Loading...
HomeMy WebLinkAboutSN 3928 Narrative Wexford Walkover over Jolly 2017 BIENNIAL BRIDGE INSPECTION SUMMARY  WEXFORD ROAD WALKOVER OVER JOLLY ROAD  STRUCTURE NUMBER – 3928  CITY OF LANSING, MI  October 13, 2017 Tetra Tech 401 South Washington Square, Suite 100, Lansing, MI 48933 Tel 517.316.3930 Fax 517.484.8140 www.tetratech.com The Wexford Road Walkover over Jolly Road is a single‐span painted  steel truss constructed in 1968 and partially repainted in 2003. The  walkover is in poor condition.  SUPERSTRUCTURE  At the south stair, minor section loss is visible, but painted over, on the  bottom of the stringers of the lower stair run. There is also minor painted over section loss on the  members of the intermediate platform. The fencing is loose at the bottom of the north stair stringer and  on the bottom west side of the intermediate platform.    At the north stair, there is heavy corrosion and holes in the web of both stringers at the base of the  lower stair run. The north stringer has one hole at the base (1” x 2”). The south stringer four holes at the  base (2” x 5”, 3” x 5”, 3” x 5” and 1/2" x 1 1/2") that have resulted in loss of more than half of the web at  the base. The south stringer also has a small hole (1/2" x 1 1/2") in the web at the 4th step from the  bottom. The anchor plate at the bottom of the north stringer is half corroded away. The concrete  foundation curb is spalled under the north stringer anchor plate and is providing little support.  There is  heavy section loss on the bottom of the middle fence post on the north stringer.  The north intermediate stair platform is framed with steel channel beam members. There is section loss  visible on all of the beams which was painted over. There are holes in the web of the east beam. The  west beam is also rusted through and was repaired with a plate. The top tread of the lower stair run was  partially corroded away and is supported with a welded plate. The column base plates are warped and  cupped.  Some of the wire ties at the bottom of the pedestrian fencing at the stairs are missing (10 total counted).  Each main span support consists of two vertical columns and two diagonal braces. There is scattered rust  on the posts and bracing members. All of the base plates have light corrosion around the edges.  At the main span truss, the east bottom chord member has scattered rust and rust holes along most of  both bottom edges over the inside westbound lane and some scattered holes along the both bottom  edges over the inside eastbound lane. It is completed corroded through along most of the east edge  over the inside westbound lane. There are rust holes at the northeast end of the 2nd bottom diagonal  brace from the south and the southwest end of the 1st bottom diagonal brace from the north. There is  rust at the welds at the top chord connections.  The underclearance sign on the east side of the truss over the westbound lanes is missing the nut on one  of the upper attachment bolts. There is a hole in the pedestrian fencing on the east side of the main  truss.          Tetra Tech 401 South Washington Square, Suite 100, Lansing, MI 48933 Tel 517.316.3930 Fax 517.484.8140 www.tetratech.com FOUNDATIONS  At the curb under the bottom of the north stair stingers, the concrete is spalled under the base plate of  the north stringer. The stair foundation pedestals have some minor cracking or scaling. The foundation  pedestals for the main span columns are in generally good condition.  There is new guardrail in front of both south and north truss foundation pedestals.   RECOMMENDATIONS:   Perform welded repairs:  o Bottom of main span east truss bottom chord.  o First diagonal cross brace from north.  o Both stringers at bottom of north stairs.  o East beam at north intermediate platform.   Patch concrete foundation at base of north stairs.   Replace missing wire ties for the fencing.   Reattach the underclearance sign on the east side of the main span.   Repair hole in the pedestrian fencing on the east side of the main truss.