Loading...
HomeMy WebLinkAboutSN 3957 Narrative H Franks Schl Walkover over Wise 2017 BIENNIAL BRIDGE INSPECTION SUMMARY  HARLEY FRANKS SCHOOL WALKOVER OVER WISE ROAD  STRUCTURE NUMBER – 3957  CITY OF LANSING, MI  October 13, 2017  Tetra Tech 401 South Washington Square, Suite 100, Lansing, MI 48933 Tel 517.316.3930 Fax 517.484.8140 www.tetratech.com The Harley Franks School Walkover over Wise Road is a single span  aluminum truss constructed in 1975. The walkover is in generally good  condition.  SUPERSTRUCTURE  At the lower east stair, the 11th stair tread from the bottom is bent on the backside at the west end.    At the upper west stair, the first stair tread from the intermediate landing is bent. There is minor  damage to the bottom base angle on the west stringer. There are vines in the fencing at the west stair  that appear to have been cut but not removed. The small sections of fencing between the top of the  stairs and the main span are loose and twisted.  On the main truss, the horizontal decorative panel is loose at the east end of the north face. The first  three sets of connections (out of five) at the east end of the panel are broken. Numerous wire ties at the  bottom of the pedestrian fencing are missing (49 total counted).  There are utility wires under the main span at the east end. One wire is touching the truss, but appears  to have additional insulation around the wire at that location.  FOUNDATIONS  The west stair concrete foundation pedestal has heavy leaching map cracks. The west main span  concrete foundation pedestal has moderate leaching map cracks. There are cracks in the grout under the  column base plates.  The east main span concrete foundation pedestal has heavy leaching map cracks. It also has minor  deterioration on top at the northwest corner and scaling at the top of the southeast and southwest  corners. At the east stair foundation pedestal, there are heavy leaching map cracks with scaling at the  top southeast and southwest corners. The grout under the column base plates is disintegrating.  The guardrail in front of the west stairs and foundations is dented at each end due to traffic impacts. It is  also low, measuring 1’‐3 1/2" from grade to top of rail.  RECOMMENDATIONS:   Reattach or removed loose decorative panel on north face of main truss.   Chip and patch concrete foundation pedestals as required.   Chip and place new non‐shrink grout where required under the column base plates.   Replace missing wire ties for the fencing.   Install new sections of fencing between the stairs and main span.   Upgrade guardrail at west stairs and foundations.